INSTALLATIONS
Cerama-Tech is a proven and widely accepted ceramic insulation coating which has been installed in millions of square feet of applications. It is also utilized in commercial, industrial and residential roofing, interior and exterior painting, metal buildings, pipes, boilers, boat bottoms, flotation devices and sound rooms.
ELASTOMERIC
The Submitted sample was prepared as a free film over a urethane substrate and tested in accordance with ASTM - D2370. Results show an elongation at break of 300. Cerama-Tech is water-based acrylic which emits low odor and complies with strictest Federal and local regulations. Cerama-Tech is perfect for renovating occupied building space.
ABUSE RESISTANT
Cerama-Tech cures to a super hard finish that will remain impervious to outside elements and atmospheric conditions.
MODERATE COST
Although
Cerama-Tech looks expensive, it is very competitive in price with normal coatings. Since it is easy to clean and does not require repainting for many years, maintenance costs are also less.
FADE RESISTANT
Factory testing along with outside application tests have shown that the color retention factor remains constant, and no fading has occurred on the product tested in the Weatherometer for over 5000 hours, or the equivalent of over thirteen years. Added results show -- Durability, Grain Crack Resistance and Film Integrity -- EXCELLENT--.
WARRANTY
Cerama-Tech coating features a 15 year limited warranty against chipping, flaking and peeling. See the manufacturers full written warranty for more specific information.
MILDEW RESISTANT
Cerama-Tech does not trap moisture. This feature combined with a long term mildewcide gives the coating a chemical composition that does not contribute to the growth of mildew.
SUPPORT SERVICE
Our specialty-trained support team will assist you with your specific requirements. Services include specification assistance, technical information, custom applications, etc.
WASHABLE
Cerama-Tech is not damaged by water. Most dirt, light scuffs, crayon, or pencil marks, lipstick, grease pencil, and most other types of coverings can be removed with a scrub brush and most commercial cleaning agents.
INSULATION
Working in the principal of Reflectability and Emissivity, creating a reflective barrier,
Cerama-Tech has been able to show energy savings of over 50% on heating and cooling costs.
FIRE RETARDANT
Cerama-Tech substantially exceeds Standard Building Code requirements for Type 1 and Class A materials. Cerama-Tech has had both ASTM - D3806 and ASTM - E 84 flame spread testing performed by 2 separate approved testing laboratories with a resulting flamespread of 10 or less, and smoke contribution of less than 5.0.
For additional information contact:

Ceram-Tech-Int

1646 Via Del Mesonero
San Diego, CA 92173
(619) 690 - 0773
(888) 236-5271

ASBESTOS and LEAD ENCAPSULANT
Cerama-Tech exceeds the E.P.A.. requirements for rating as an Acceptable Encapsulate for asbestos. Example: In one test performed on a 300 degree pipe contaminated with asbestos, it lowered the outside temperature of the pipe 100 degrees, while encapsulating the asbestos.

Composition and Materials:

Cerama-Tech is a nontoxic water based vinyl acrylic coating emitting a mild odor and complying with the strictest federal, states and local VOC regulations.

Container and Weight:

Cerama-Tech is packaged in 5 gallon plastic containers weighing approximately 56.5 lbs. Shelf life is 2 yrs.

Coverage:

Cerama-Tech is applied at a rate of 250 square feet per gallon on a smooth. prepared surface and 80 square feet on a rough or porous surface. The coating may be rolled, brushed, or sprayed over properly prepared galvanized and ferrous metals, cementitous substrate, ceramic tile, wood surfaces, plaster, gypsum board, painted surfaces, bituminous materials, and masonry. It may be tinted to match any paint color.

Product Handling and Storage:

Materials are delivered on site in original, sealed, new containers bearing manufacturer's name, name of materials, and batch number. For material to be tinted, a small capped hole is on the lid. Store unopened containers under protective cover, free from foreign matter and residue, and at temperatures between 40 F (5 C) and 100 F (38 C).
• Do not allow
Cerama-Tech to freeze.
• Do not allow water to mix with
Cerama-Tech.

Codes and Standards:

Cerama-Tech meets or exceeds:
• Building code requirements for Type 1 Class A materials.
• Environmental Protection Agency requirements as an Acceptable Encapsulate for Asbestos and Lead.
• Complies with Volatile Organic Compound regulations.

Surface Preparation:

Clean and prepare surfaces according to manufacturers instruction for each particular substrate condition.
Provide barrier coats over incompatible primers or remove and re-prime.

Protective Coverings:

Provide protections for duration of finishing work. Protect work for other trades against damage, marking, and injury. Repair damage caused by painting.


Solvent Resistance (One hour soak)
Water: No Change
Detergent: No Change
Bleach: No Change
Simple Green: No Change
Stain Resistance:
Water: No visible staining
Blood: No visible staining
Urine: No visible staining
Coffee: No visible staining
Tea: No visible staining
Lipstick: No visible staining
Crayon: No visible staining